An interaction gives you an estimate of how a slope changes. It does not, by itself, tell you the slope at a plausible value of the moderator. Before saying that a relationship is stronger under one condition, identify the moderator metric and check the conditional estimate and its uncertainty.
Use the 120-case observed workshop. Here y is a continuous outcome, x is the focal predictor and z changes the x-to-y slope. The file uses synthetic measurements, so the purpose is to learn the calculation rather than attach a business meaning to x or z.
Make z a moderator, not just a control
In Analyze… → Regression, choose Graph-defined Path Analysis / PROCESS. Set Outcome to y and Focal predictor to x. Create x → y. Remove z from Controls if you carried the field over from another model. Choose Add moderator, select z and set its continuous Scale / coding. Use Moderate a path for x → y. Check that the preview contains x, z and their product, not merely two main effects. Review the cases and final metric, record your inference settings and calculate. QuickPLS Pro Regression guide.
For continuous z, use the printed sample mean and mean ± one sample standard deviation. They are fixed probes based on the analysed sample and reported in the final metric. Values of −1, 0 and +1 only describe those particular probes when the metric and data actually put them there. For a binary moderator, the documented probes are 0 and 1. Label those categories; they are not low and high points on a continuous scale.
Calculate one conditional slope on paper
In the equation fitted y = intercept + b₁x + b₂z + b₃xz, the slope for x at z = w is b₁ + b₃w. As a separate illustration, let b₁ = 0.30 and b₃ = −0.12. At hypothetical moderator values −1, 0 and +1, the slopes are 0.42, 0.30 and 0.18. The negative interaction means that higher z is associated with a smaller slope, not that the slope turns negative at every higher value. These figures are invented for the arithmetic; use the saved workshop coefficients and actual probes to make a comparison about that file.
To understand the uncertainty, keep b₁ and b₃ together. The variance of their linear combination at w includes their covariance as well as their individual variances. This is why calculating endpoints from separate coefficient intervals, or using the same uncertainty width at every probe, is not a substitute for the reported conditional interval.
Read a region as a region, not as an effect size
Where eligible, the Johnson–Neyman output identifies values of the moderator for which the slope differs from zero under the stated confidence procedure. The boundary marks where the interval begins or stops excluding zero. It does not identify an abrupt change in the underlying relationship. Always compare the reported interval or boundary with the observed moderator range. A threshold outside the data is not practical evidence that responses change at that point. Even within the range, inspect whether cases near the boundary are represented well.
The slope plot and Johnson–Neyman displays in the documented workflow remain two-sided at the selected confidence level. Keep them separate from an effect-specific bootstrap interval, especially if an effect test was configured as one-sided. If a region is not supported for your setup, report that status. Do not draw your own boundary from the appearance of a screenshot. Johnson and Neyman's original framework as developed for interaction probing by Bauer and Curran.
Try it: In the illustrative equation, does the fact that 0.18 is positive tell you it is statistically distinguishable from zero? No. That decision requires the conditional uncertainty at the specific moderator value.
Report template: “We estimated the interaction of x and continuous z, with both main effects. The slope of x at [actual z] was [estimate and interval]. The eligible two-sided Johnson–Neyman region was [range], of which [part] lay within observed z values.” State the scale and sample before giving the region.