Open the delivery practice file and look at the last two cases. In m09, the A column contains 0.5. In m10, the B column is blank. Both cases are excluded from the same QuickPLS Pro teaching analysis, but each needs a different explanation. If your Methods section simply says “two incomplete cases were dropped,” it misreports what happened.
This guide shows how to tell the two cases apart, record the decisions without altering the original file, and confirm that the calculation used the intended cases.
Read the original values first
Download memberships.csv. Use the m-case file, not the similarly named delivery file from the separate paper tutorial. Here A is capacity, B is reach, C is coordination and Y is successful delivery. The values are already calibrated; 1 denotes full inclusion in a set and 0 full exclusion.
| Case | A: Capacity | B: Reach | C: Coordination | Y: Delivery | What needs a decision? |
|---|---|---|---|---|---|
| m09 | 0.5 | 1 | 0 | 1 | A is observed and exactly at the crossover. |
| m10 | 1 | blank | 1 | 1 | B membership is unavailable. |
For m09, the existing capacity membership is exactly on the boundary: the case is not more in the high-capacity set than out of it, nor more out than in. It is an observed, meaningful membership. It does not say this project had a 50% chance of successful delivery. For m10, there is no value to interpret. A blank B does not tell you the project lacked reach. For more on the distinction between a measurement and a calibrated membership, see Charles Ragin’s explanation of fuzzy-set calibration.
Open the data at its stored precision if you suspect the display has rounded a value. A recorded 0.4997 may display as 0.50, but it is not an exact crossover. And if a code such as 99 represents “not recorded” in your own data, confirm it against the codebook rather than reading it as a very high score.
Record each case decision in QuickPLS Pro
- In a writable project, import memberships.csv. Confirm ten source cases, the m-case identifiers and the A, B, C and Y columns. Leave the CSV intact.
- Select the imported dataset and open Analyze… → Fuzzy-set Qualitative Comparative Analysis → Method settings. Assign A, B and C as conditions and Y as the outcome. Select Presence of the outcome, use case_id as the identifier and select the existing-membership option for all four membership columns. Check the original rows rather than recalibrating already supplied values.
- Expand Data: missing values and exact crossovers. For this exercise, use the Missing selected values option that excludes affected cases and records each exclusion. It handles m10, where the selected condition B is missing.
- Enter 9 in Source row to exclude, enter a reason such as A is exactly 0.5 at the capacity crossover, and choose Record deliberate crossover exclusion. The entry 9 identifies the ninth data row, not the ninth line when counting the header. Cross-check the case identifier m09 as well as the row number. If you have reordered the actual source file, do not assume the practice row number still applies.
- Keep the two reasons in your decision notes. If you run the documented baseline, select its completed result and inspect the cases and recorded exclusions. The check is 10 imported − 1 crossover exclusion − 1 missing-condition exclusion = 8 analysed. You should be able to identify m01 through m08, not just see a count of eight.
What if the completed result shows nine cases? Start by checking whether you recorded the deliberate exclusion as well as setting the missing-value policy. Then check that the displayed result belongs to this calculation. Editing the form after a run does not alter the cases used by that older result.
Why not fill the blank or round 0.5 away?
The actual values show why these apparent shortcuts change the analysis. Suppose you forced m09’s capacity membership onto one side of the boundary. Treating A as absent places it in pattern 010 in A, B, C order. The existing case in 010, m03, has Y = 0; m09 has Y = 1. Treating A as present instead would put m09 in 110, where m07 already has Y = 1. The two arbitrary choices can add evidence to quite different configurations.
The blank produces a different problem. Substituting 0 for m10’s B assigns it to 101; substituting 1 assigns it to 111. Neither is observed in m10’s record. These are hand checks of hypothetical recoding, not recommended fixes or reported QuickPLS results. These examples show how replacing a recorded value can change the configuration to which a case belongs, and therefore change the analysis.
In your own study, investigate an exact crossover against the case evidence and calibration rationale. For missingness, first look for a reliable original value and examine whether missingness is concentrated in a particular kind of case. An exclusion policy changes who is represented in the analysis. Do not treat the result from retained cases as evidence about the cases you could not analyse, and do not revise an anchor just because the alternative produces a neater solution.
What to write in your methods section
We retained the raw case records and used the supplied membership values. In the ten-case teaching dataset, m09 was excluded by a deliberate crossover decision because its membership in the capacity set was exactly 0.5. Case m10 was excluded by the missing-value policy because reach, a selected condition, was not recorded. Eight cases entered the analysis.
Try this before moving on: If a source value is exactly 0, would you list it as missing? No. Zero is observed full non-membership. If the value only looks like 0.5 in a table, would you record an exact-crossover exclusion? Not without checking the stored value. The useful rule is to match the decision to the source evidence and make the reason traceable.