At x = 0, the resource case in the QuickPLS Pro calibration exercise has an assigned set membership of 0.05. The saved indirect fit predicts about 0.070 instead. That difference is not an error. One curve is fitted to all six case-level assignments; it does not have to reproduce each assignment exactly.
An indirect calibration can be useful when evidence supports initial membership judgements for cases and you want a systematic mapping from their original raw scores. This guide covers the particular binomial-logit option in Advanced fsQCA Calibration. Other procedures called “indirect calibration” need not fit the same curve.
Find the actual inputs to the fit
Open a working copy of the research choices project linked on the method page. Select the completed calibration example, open Advanced calibration and choose the calibration.csv study with the Indirect binomial-logit assigned memberships revision. Use Load selected setup and verify x is the condition input. Y stays as supplied outcome membership.
| Case | x | Assigned target | Fitted membership, approximately |
|---|---|---|---|
| k01 | 0 | 0.05 | 0.070 |
| k02 | 1 | 0.20 | 0.175 |
| k03 | 2 | 0.40 | 0.374 |
| k04 | 3 | 0.60 | 0.626 |
| k05 | 4 | 0.80 | 0.825 |
| k06 | 5 | 0.95 | 0.930 |
Under Preview calibrated cases, compare original x, your targets and the fitted values. The last column above is a hand check, using the archived intercept −2.5833093 and slope 1.0333237. At x = 2 the logit is about −0.517; transforming it with 1 ÷ [1 + exp(−logit)] gives about 0.374. A negative intercept does not mean a negative set membership. The fitted output describes belonging to a set, not the probability Y will happen.
The saved record shows six fitting observations and seven iterations. This example has no exact crossover to exclude. In other cases, fitting uses nonmissing original observations before subsequent fsQCA exclusions. Keep the fitting sample and the later analysis sample separate.
What to do if the fit fails
Start with the variation in x. Imagine a separate diagnostic copy where every resource score unexpectedly imports as 2. At identical x values the fit cannot identify a separate slope, no matter how many iterations it gets. Check the source column, decimal choice and import preview before adjusting fit settings.
Perfect separation is a different issue. Imagine binary assignments that flip from 0 to 1 exactly once as ordered x increases, with no exceptions. The fitted curve may keep getting steeper rather than yielding a stable finite estimate. That is a diagnostic illustration, not an observed failure of the six-case example. Inspect the assignments, variation and convergence information. Do not treat a failed fit as producing zero memberships.
If the fit succeeds but one predicted value differs slightly from its assignment, first check whether you are comparing the right columns. Then ask whether the overall fitted direction and crossover make sense. A converged curve does not make a poorly justified set definition credible.
After checking the fit, preview the calibrated truth table as a separate step. Save the calibration revision, name the procedure and retain the original case assignments. In the Methods section, say how those assignments were made and how many rows the fit used; separately report any exclusions in the fsQCA.
Check your reading: If the preview gives 0.374 for a case you assigned 0.40, should you replace the fitted value with its target? No. Doing so would silently switch that case away from the fitted calibration.